2819-2823 Conductivity/Resistivity Sensors
Signet Conductivity/Resistivity Sensors are designed to provide versatile installation and accurate sensing across a very broad dynamic range. Coupled with Signet-patented measuring circuitry a three decade range with ±2% of reading accuracy is achieved without the need for troublesome sensor platinization.
2819-2823 Data Sheet |
 |
2839-2842 NPT Conductivity/Resistivity Electrodes
The 2839-2842 Conductivity/ Resistivity Electrodes are available in four cell constants from 0.01 to 10.0, and are suitable for a wide variety of applications from high purity water quality monitoring to demineralizer regeneration. 316SS electrode surface finishes are controlled in a precision bead blasting operation to ensure measurement accuracy and repeatability. Double threaded connections in either 3/4 in. NPT or ISO 7/1-R 3/4 enable quick and easy installation in submersible or in-line configurations.
2839-2842 Data Sheet |
 |
2839-2842 DryLoc™ Conductivity/Resistivity Electrodes
The 2839-2842 DryLoc™ Conductivity/ Resistivity Electrodes are available in four cell constants from 0.01 to 10.0, and are suitable for a wide variety of applications from high purity water quality monitoring to demineralizer regeneration. 316SS electrode surface finishes are controlled in a precision bead blasting operation to ensure measurement accuracy and repeatability, and the PEEK insulator and process connections are injection over-molded to minimize variance between electrodes. The DryLoc electrode connector quickly forms a robust assembly with the 2850 Conductivity/Resistivity Sensor for submersible and in-line installations.
2839-2842 DryLoc Data Sheet |
 |
2850 DryLoc™ Conductivity/Resistivity Sensor
The 2850 Conductivity/Resistivity Sensors provide two-wire 4 to 20mA output without the expense of local display and other luxuries available in full-featured transmitters. Eight 4 to 20mA output ranges for each electrode cell constant, plus the ability to invert each range, are selectable by the user in the field. These sophisticated sensors also provide a digital (S3L) interface, another example of leading-edge technology from Signet. The DryLocT electrode connector quickly forms a robust assembly for submersible and in-line installations.
2850 DryLoc™ Data Sheet |
 |
8850 ProcessPro Conductivity/Resistivity Transmitter
The Signet 8850 Conductivity/Resistivity Transmitter is designed for broad application and ease of setup and use. The unit can be used for conductance, resistance, or TDS signal transmission and display. Full-microprocessor based electronics allow wide operating range, and long term signal stability.
8850 Data Sheet |
8860 Dual Channel Conductivity/Resistivity Controller
The Signet 8860 Dual Channel Conductivity/Resistivity Controller is a two-channel input device equipped with three scaleable 4 to 20 mA outputs and four programmable relays. A selector switch activates two open collector outputs in place of two of the relays for extraordinary output versatility. Dual input and advanced control capability, including percent rejection, difference and ratio calculations, together with Signet Conductivity Sensors, form the perfect measurement and control system for water treatment applications and more.
8860 Data Sheet |
 |
5800CR ProPoint Conductivity/Resistivity Monitor
The Signet 5800CR Conductivity/Resistivity Monitor is equipped with a scaleable 4 to 20 mA output and two programmable relays for simple and convenient process control and monitoring. Temperature is selectable for display in either °C or °F, and compensation is automatic and programmable.
5800CR Data Sheet |
5900 ProPoint Salinity Monitor
The Signet 5900 Salinity Monitor utilizes conductivity sensors to provide direct reading, including calibration, of salinity in parts per thousand (PPT). Equipped with a scaleable 4 to 20 mA output and two programmable relays, the monitor requires 12 to 24 Volts, AC or DC, and can be used with Signet 2822 and 2823 Conductivity Sensors (10.0 and 20.0 cell constants, resp.) Temperature is selectable for display in either °C or °F, and compensation is automatic.
5900 Data Sheet |